MEC-P20MS 20-ZONE SS EMG. ALARM MONITOR CONTROLLER PANEL
Share







MEC-P20MS 20-ZONE STAINLESS STEEL EMERGENCY ALARM MONITOR CONTROLLER PANEL
miTEC's newly launched MEC-P20MS ‘Multi-Purpose’ Alarm Monitoring Main Panel can monitor the alarm input status of up to 20 zones in real time, and with the expansion module MEC-P20ES, the whole system can be expanded to a maximum of 100 zones, which is flexible enough to meet the security monitoring needs of different scenarios.
The system is particularly suitable for all kinds of properties and public facilities, including commercial buildings, flat houses, schools, clinics, hospitals, elderly centres, community facilities, shopping malls and industrial buildings, providing a highly integrated surveillance solution. With RS485 serial technology, it can significantly reduce cabling costs and improve signal stability and system expansion flexibility. MEC-P20MS supports various input types, including NO, NC, miTEC MECK-KIT emergency call button, flood detector, etc. Users can quickly configure them according to the actual needs of different zones through the DIP switches. Each of the 5 zones can be customised to suit the application flexibly.
Key Features
-
20 Monitoring Zones: Monitor up to 20 alarm zones with one panel.
-
Expandable System: Add up to 4 expansion panel, monitor up to 100 zones total.
-
Flexible Input Options: Works with NO/NC switches, MECK-KIT, and water level sensors.
-
Easy Zone Labeling: Change zone names using editable or handwritten labels.
-
Backup Power Ready: Built-in battery slot supports miTEC MPE-CH for 2 hours of emergency backup.
-
Quick Setup: DIP switches allow fast configuration — no calibration needed.
-
Compatible with Old Systems: Use the MEC-SB board to connect older devices for individual alarm output for each zone.
Technical Specifications
Parameter | Details |
---|---|
Number of Zones | 20 zones per panel (expandable up to 100 with 4 expansions) |
Power Input (Master Panel) | AC 200–240V |
Power Output | DC 12V, 1A (Powers up to 2 expansion panels) |
External PSU Input | DC 13.8V (Recommend miTEC PHM76-138-A) |
Panel Standby Current | 90mA |
Panel Alarm Current | 285mA |
MECK Alarm Current per Zone | 80mA |
Communication Protocol | RS485 |
Relay Output Type | N.O. / COM / N.C. (Dry Contact DC24V, 3A Max.) |
Panel Modes | Master Mode / Repeater Mode (configurable via DIP B1) |
Material | Stainless steel front panel |
Dimension | 220 x 190 x 82mm |
Applications
- Fire Door Monitoring : Instantly report whether the fire door is not closed or has been forced open to enhance the efficiency of fire response.
- Toilet Emergency Call Monitoring : Elderly or disabled persons press the help button, an audio-visual alarm will be sent out immediately and the management office will be notified.
- Pump Room / Elevator Slot Water Leakage Detection Monitoring : When flooding is detected, the system will immediately issue an alarm to prevent property loss and electrical hazards.
Upgrade Compatibility : MEC-SB Signal Board
- Converts signals from legacy emergency buttons and magnetic contacts
- Plug & play setup with DIP A configuration — no rewiring required
MEC-P20 : The Smarter Alarm Monitoring Choice
Designed for Hong Kong’s high-density urban landscape, the MEC-P20 series offers:
- Cost Efficiency: RS485 wiring reduces installation labor; built-in battery support avoids external units
- Smart Management: Remote viewing via phone or PC reduces patrol workload by 30%
- Enhanced Safety: Early alerting from water level, fire, and unauthorized access sensors
*Editable Easy Label for Download*
https://shorturl.at/NiA6Y